§25.1713 Fire Protection; EWIS

CS-25 · Subpart H — Electrical Wiring Interconnection System · at CS25-28 (current)

Text in force at CS25-28: from CS25-5, effective 5 Sep 2008.

(See AMC 25.1713) (a) All EWIS components must meet the applicable fire and smoke protection requirements of CS 25.831(c) and CS 25.863. (b) EWIS components that are located in designated fire zones and are necessary during emergency procedures must be at least fire resistant. (c) Insulation on electrical wire and electrical cable, including materials used to provide additional protection for the wire and cable installed in any area of the aeroplane, must be self-extinguishing when tested in accordance with the applicable portions of Part I of Appendix F.