§29.1359 Electrical system fire and smoke protection.

14 CFR 29 · Equipment · Electrical Systems and Equipment · at 29-59 (current)

Text in force at 29-59: from 29-42, effective 11 Sep 1998.

(a) Components of the electrical system must meet the applicable fire and smoke protection provisions of Secs. 29.831 and 29.863. (b) Electrical cables, terminals, and equipment, in designated fire zones, and that are used in emergency procedures, must be at least fire resistant. [(c) Insulation on electrical wire and cable installed in the rotorcraft must be self-extinguishing when tested in accordance with Appendix F, Part I(a)(3), of part 25 of this chapter.]

63 FR 43285 · Source