Bombardier Inc. BD-700-2A12: certification basis
Basis entries as written on the TCDS
-
REG
BD-700-2A12 27 September 2018
TCCA Certification Date
Not linked to provisions yet: the line is not interpreted, or its document is not in the dataset.
-
REG
Refer to Transport Canada TCDS A-177.
TCCA Certification Basis
Not linked to provisions yet: the line is not interpreted, or its document is not in the dataset.
-
REG
CS-25 Amendment 13, effective on 10 June 2013, except: • CS 25.1322 Amendment 1 for the Primary Flight Displays (PFD) of the Proline Fusion Avionics Suite. • CS-ACNS issue 4, Subpart E Section 3 for aircraft incorporating BD-700-2A12 MODSUMS: 700P2560005 (DCCP-G7/8-0058) Emergency locator transmitter distress tracking. • CS 25.353 Amendment 22 for aircraft incorporating BD-700-2A12 MODSUMS 700T7095076, 700T7095110 and 700T7095078 or SB 700-34-7528.
Includes CS-25 through CS25-13 · current is CS25-28, 15 revisions later
Includes CS-25 §25.1322 through CS25-1 · current is CS25-28, 27 revisions later
Includes CS-25 §25.353 through CS25-22 · current is CS25-28, 6 revisions later
Expands to 388 provision links ! 1 text missing · shown below
-
◆ SPECIAL
SC CRI Title
-
◆ SPECIAL
B-02 Flight Envelope Protection Design
-
◆ SPECIAL
B-03 Flight in Icing Conditions
-
◆ SPECIAL
B-04 Stalling and Scheduled Operating Speeds
-
◆ SPECIAL
ISO9001 Certified. Page 26 of 36
-
◆ SPECIAL
SC CRI Title
-
◆ SPECIAL
B-09 Static Directional, Lateral and Longitudinal Stability and Low Energy Awareness
-
◆ SPECIAL
C-11 Automatic Braking System Structural Loads
-
◆ SPECIAL
D-03 In-Flight Fire – Composite and Unusual Construction
-
◆ SPECIAL
D-09 Control Surface Position Awareness / Electronic Flight Control Systems
-
◆ SPECIAL
D-13 High Altitude Operation / High Cabin Heat Load
-
◆ SPECIAL
D-21* Side Facing Seats and Inflatable Passenger Restraints
-
◆ SPECIAL
E-05 Water / Ice in Fuel System
-
◆ SPECIAL
E-11 Airworthiness Standard for Aircraft Operations Under Falling and Blowing Snow
-
◆ SPECIAL
F-04 Airborne Systems and Network Security
-
◆ SPECIAL
F-05 HIRF Protection
-
◆ SPECIAL
F-06 Flight Instrument External Probes – Qualification in Icing Conditions
-
◆ SPECIAL
F-08 Flight Recorders, Data Link Recording
-
◆ SPECIAL
F-21 Data Link Services for the Single European Sky
-
◆ SPECIAL
F-25 Rechargeable Lithium battery installations
-
◆ SPECIAL
F-26 Non-Rechargeable Lithium battery installations
-
◆ SPECIAL
F-30 Synthetic Vision on Head Up Display
-
◆ SPECIAL
F-31 Enhanced Flight Vision System with Operational Credit
-
◆ SPECIAL
F-41* Therapeutic Oxygen System
-
◆ SPECIAL
* These Special Conditions, applicable to the Interiors Installation STC, form part of the certification basis for approved interiors of the BD-700-2A12.
-
ELOS
ESF CRI Title
-
ELOS
B-12 Out of Trim
-
ELOS
D-06 Pilot Compartment View – Hydrophobic Coatings
-
ELOS
D-22 APU Access Door
-
ELOS
D-23 Access Panel Doors
-
ELOS
D-24 Flight Control System Failure Criteria
-
ELOS
D-27* Class B Baggage Compartment
-
ELOS
D-28* Lavatory Ashtray
-
ELOS
D-29* No Smoking Placards
-
ELOS
E-18 Fuel Filter Location
-
ELOS
ISO9001 Certified. Page 27 of 36
-
ELOS
ESF CRI Title
-
ELOS
E-19 Thrust Reverser Actuation System (TRAS) Zone Adjacent to Designated Fire Zone TCCA IP P-11 Powerplants Fire Extinguishing System Bottle Sharing (EASA CRI E-21)
-
ELOS
F-34 Non-Magnetic Standby Compass TCCA IP OS-104* Minimum Mass Flow of Supplemental Oxygen (EASA CRI F-38)
-
ELOS
F-40 Maximum Allowable Overlapping Intensities on Position Lights
-
ELOS
G-02 Green Arc for Powerplant Instrument
-
ELOS
* These Equivalent Safety Findings, applicable to the Interiors Installation STC, form part of the certification basis for approved interiors of the BD-700-2A12.
-
OTHER
9.1 Noise See TCDSN no. EASA.IM.A.009.
-
OTHER
9.2 Fuel Venting ICAO Annex 16, Volume II, Amendment 7, Part II.
-
OTHER
ISO9001 Certified. Page 28 of 36
- Exemptions: none recorded.
Entry 3 expanded
Subpart A — General CS-25 1 section
| Section | Title | Cut-off | Text version | Changed since | Status |
|---|---|---|---|---|---|
| §25.1 | Applicability | CS25-13 | CS25-11 | 0 | ✓ Text available |
Subpart B — Flight CS-25 41 sections
| Section | Title | Cut-off | Text version | Changed since | Status |
|---|---|---|---|---|---|
| §25.20 | Scope | CS25-13 | CS25-0 | 1 | ✓ Text available |
| §25.21 | Proof of compliance | CS25-13 | CS25-6 | 4 | ✓ Text available |
| §25.23 | Load distribution limits | CS25-13 | CS25-0 | 0 | ✓ Text available |
| §25.25 | Weight Limits | CS25-13 | CS25-0 | 0 | ✓ Text available |
| §25.27 | Centre of gravity limits | CS25-13 | CS25-0 | 0 | ✓ Text available |
| §25.29 | Empty weight and corres- ponding centre of gravity | CS25-13 | CS25-0 | 0 | ✓ Text available |
| §25.31 | Removable ballast | CS25-13 | CS25-0 | 0 | ✓ Text available |
| §25.33 | Propeller speed and pitch limits | CS25-13 | CS25-0 | 0 | ✓ Text available |
| §25.101 | General | CS25-13 | CS25-2 | 1 | ✓ Text available |
| §25.103 | Stall speed | CS25-13 | CS25-3 | 1 | ✓ Text available |
| §25.105 | Take-off | CS25-13 | CS25-3 | 1 | ✓ Text available |
| §25.107 | Take-off speeds | CS25-13 | CS25-3 | 3 | ✓ Text available |
| §25.109 | Accelerate-stop distance | CS25-13 | CS25-0 | 2 | ✓ Text available |
| §25.111 | Take-off path | CS25-13 | CS25-3 | 1 | ✓ Text available |
| §25.113 | Take-off distance and take- off run | CS25-13 | CS25-9 | 1 | ✓ Text available |
| §25.115 | Take-off flight path | CS25-13 | CS25-0 | 0 | ✓ Text available |
| §25.117 | Climb: general | CS25-13 | CS25-0 | 0 | ✓ Text available |
| §25.119 | Landing climb: all engines operating | CS25-13 | CS25-3 | 3 | ✓ Text available |
| §25.121 | Climb: one-engine-inoperative | CS25-13 | CS25-3 | 2 | ✓ Text available |
| §25.123 | En-route flight paths | CS25-13 | CS25-3 | 2 | ✓ Text available |
| §25.125 | Landing | CS25-13 | CS25-3 | 3 | ✓ Text available |
| §25.143 | General | CS25-13 | CS25-13 | 6 | ✓ Text available |
| §25.145 | Longitudinal control | CS25-13 | CS25-3 | 3 | ✓ Text available |
| §25.147 | Directional and lateral control | CS25-13 | CS25-0 | 2 | ✓ Text available |
| §25.149 | Minimum control speed | CS25-13 | CS25-0 | 1 | ✓ Text available |
| §25.161 | Trim | CS25-13 | CS25-0 | 0 | ✓ Text available |
| §25.171 | General | CS25-13 | CS25-0 | 0 | ✓ Text available |
| §25.173 | Static longitudinal stability | CS25-13 | CS25-0 | 1 | ✓ Text available |
| §25.175 | Demonstration of static longitudinal stability | CS25-13 | CS25-0 | 0 | ✓ Text available |
| §25.177 | Static directional and lateral stability | CS25-13 | CS25-11 | 2 | ✓ Text available |
| §25.181 | Dynamic stability | CS25-13 | CS25-0 | 0 | ✓ Text available |
| §25.201 | Stall demonstration | CS25-13 | CS25-0 | 2 | ✓ Text available |
| §25.203 | Stall characteristics | CS25-13 | CS25-0 | 0 | ✓ Text available |
| §25.207 | Stall warning | CS25-13 | CS25-7 | 3 | ✓ Text available |
| §25.231 | Longitudinal stability and control | CS25-13 | CS25-0 | 0 | ✓ Text available |
| §25.233 | Directional stability and control | CS25-13 | CS25-0 | 0 | ✓ Text available |
| §25.235 | Taxying condition | CS25-13 | CS25-0 | 0 | ✓ Text available |
| §25.237 | Wind velocities | CS25-13 | CS25-3 | 2 | ✓ Text available |
| §25.251 | Vibration and buffeting | CS25-13 | CS25-0 | 1 | ✓ Text available |
| §25.253 | High-speed characteristics | CS25-13 | CS25-11 | 3 | ✓ Text available |
| §25.255 | Out-of-trim characteristics | CS25-13 | CS25-0 | 0 | ✓ Text available |
Subpart C — Structure CS-25 60 sections
| Section | Title | Cut-off | Text version | Changed since | Status |
|---|---|---|---|---|---|
| §25.301 | Loads | CS25-13 | CS25-1 | 1 | ✓ Text available |
| §25.302 | Interaction of systems and structures | CS25-13 | CS25-1 | 0 | ✓ Text available |
| §25.303 | Factor of safety | CS25-13 | CS25-0 | 0 | ✓ Text available |
| §25.305 | Strength and deformation | CS25-13 | CS25-1 | 0 | ✓ Text available |
| §25.307 | Proof of structure | CS25-13 | CS25-1 | 0 | ✓ Text available |
| §25.321 | General | CS25-13 | CS25-0 | 0 | ✓ Text available |
| §25.331 | Symmetric manoeuvring conditions | CS25-13 | CS25-13 | 3 | ✓ Text available |
| §25.333 | Flight manoeuvring envelope | CS25-13 | CS25-13 | 2 | ✓ Text available |
| §25.335 | Design airspeeds | CS25-13 | CS25-13 | 3 | ✓ Text available |
| §25.337 | Limit manoeuvring load factors | CS25-13 | CS25-0 | 0 | ✓ Text available |
| §25.341 | Gust and turbulence loads | CS25-13 | CS25-13 | 1 | ✓ Text available |
| §25.343 | Design fuel and oil loads | CS25-13 | CS25-1 | 0 | ✓ Text available |
| §25.345 | High lift devices | CS25-13 | CS25-1 | 1 | ✓ Text available |
| §25.349 | Rolling conditions | CS25-13 | CS25-13 | 1 | ✓ Text available |
| §25.351 | Yaw manoeuvre conditions | CS25-13 | CS25-13 | 0 | ✓ Text available |
| §25.353 | Rudder control reversal conditions | CS25-22 | CS25-22 | 1 | ✓ Text available |
| §25.361 | Engine and auxiliary power unit torque | CS25-13 | CS25-8 | 1 | ✓ Text available |
| §25.362 | Engine failure loads | CS25-13 | CS25-8 | 0 | ✓ Text available |
| §25.363 | Side load on engine and auxiliary power unit mounts | CS25-13 | CS25-0 | 0 | ✓ Text available |
| §25.365 | Pressurised compartment loads | CS25-13 | CS25-0 | 2 | ✓ Text available |
| §25.367 | Unsymmetrical loads due to engine failure | CS25-13 | CS25-0 | 0 | ✓ Text available |
| §25.371 | Gyroscopic loads | CS25-13 | CS25-1 | 0 | ✓ Text available |
| §25.373 | Speed control devices | CS25-13 | CS25-1 | 0 | ✓ Text available |
| §25.391 | Control surface loads: general | CS25-13 | CS25-1 | 0 | ✓ Text available |
| §25.393 | Loads parallel to hinge line | CS25-13 | CS25-0 | 2 | ✓ Text available |
| §25.395 | Control system | CS25-13 | CS25-0 | 0 | ✓ Text available |
| §25.397 | Control system loads | CS25-13 | CS25-13 | 3 | ✓ Text available |
| §25.399 | Dual control system | CS25-13 | CS25-2 | 0 | ✓ Text available |
| §25.405 | Secondary control system | CS25-13 | CS25-3 | 1 | ✓ Text available |
| §25.407 | Trim tab effects | CS25-13 | CS25-0 | 0 | ✓ Text available |
| §25.409 | Tabs | CS25-13 | CS25-0 | 0 | ✓ Text available |
| §25.415 | Ground gust conditions | CS25-13 | CS25-0 | 1 | ✓ Text available |
| §25.427 | Unsymmetrical loads | CS25-13 | CS25-1 | 0 | ✓ Text available |
| §25.445 | Outboard fins | CS25-13 | CS25-0 | 0 | ✓ Text available |
| §25.457 | Wing-flaps | CS25-13 | CS25-0 | 0 | ✓ Text available |
| §25.459 | Special devices | CS25-13 | CS25-0 | 0 | ✓ Text available |
| §25.471 | General | CS25-13 | CS25-0 | 0 | ✓ Text available |
| §25.473 | Landing load conditions and assumptions | CS25-13 | CS25-0 | 0 | ✓ Text available |
| §25.477 | Landing gear arrangement | CS25-13 | CS25-0 | 0 | ✓ Text available |
| §25.479 | Level landing conditions | CS25-13 | CS25-0 | 0 | ✓ Text available |
| §25.481 | Tail-down landing conditions | CS25-13 | CS25-0 | 0 | ✓ Text available |
| §25.483 | One-gear landing conditions | CS25-13 | CS25-0 | 0 | ✓ Text available |
| §25.485 | Side load conditions | CS25-13 | CS25-0 | 0 | ✓ Text available |
| §25.487 | Rebound landing condition | CS25-13 | CS25-0 | 0 | ✓ Text available |
| §25.489 | Ground handling conditions | CS25-13 | CS25-0 | 0 | ✓ Text available |
| §25.491 | Taxi, take-off and landing roll | CS25-13 | CS25-0 | 2 | ✓ Text available |
| §25.493 | Braked roll conditions | CS25-13 | CS25-0 | 0 | ✓ Text available |
| §25.495 | Turning | CS25-13 | CS25-0 | 0 | ✓ Text available |
| §25.497 | Tail-wheel yawing | CS25-13 | CS25-0 | 0 | ✓ Text available |
| §25.499 | Nose-wheel yaw and steering | CS25-13 | CS25-0 | 0 | ✓ Text available |
| §25.503 | Pivoting | CS25-13 | CS25-0 | 0 | ✓ Text available |
| §25.507 | Reversed braking | CS25-13 | CS25-0 | 0 | ✓ Text available |
| §25.509 | Towing Loads | CS25-13 | CS25-13 | 2 | ✓ Text available |
| §25.511 | Ground load: unsymmet- rical loads on multiple- wheel units | CS25-13 | CS25-1 | 1 | ✓ Text available |
| §25.519 | Jacking and tie-down provisions | CS25-13 | CS25-1 | 0 | ✓ Text available |
| §25.561 | General | CS25-13 | CS25-0 | 0 | ✓ Text available |
| §25.562 | Emergency landing dynamic conditions | CS25-13 | CS25-0 | 4 | ✓ Text available |
| §25.563 | Structural ditching provisions | CS25-13 | CS25-1 | 1 | ✓ Text available |
| §25.571 | Damage tolerance and fatigue evaluation of structure | CS25-13 | CS25-1 | 2 | ✓ Text available |
| §25.581 | Lightning protection | CS25-13 | CS25-0 | 2 | ✓ Text available |
Subpart D — Design And Construction CS-25 83 sections
| Section | Title | Cut-off | Text version | Changed since | Status |
|---|---|---|---|---|---|
| §25.601 | General | CS25-13 | CS25-0 | 0 | ✓ Text available |
| §25.603 | Materials | CS25-13 | CS25-9 | 3 | ✓ Text available |
| §25.605 | Fabrication methods | CS25-13 | CS25-0 | 1 | ✓ Text available |
| §25.607 | Fasteners | CS25-13 | CS25-0 | 0 | ✓ Text available |
| §25.609 | Protection of structure | CS25-13 | CS25-0 | 1 | ✓ Text available |
| §25.611 | Accessibility provisions | CS25-13 | CS25-5 | 0 | ✓ Text available |
| §25.613 | Material strength properties | CS25-13 | CS25-1 | 0 | ✓ Text available |
| §25.619 | Special factors | CS25-13 | CS25-0 | 0 | ✓ Text available |
| §25.621 | Casting factors | CS25-13 | CS25-1 | 0 | ✓ Text available |
| §25.623 | Bearing factors | CS25-13 | CS25-0 | 0 | ✓ Text available |
| §25.625 | Fitting factors | CS25-13 | CS25-0 | 0 | ✓ Text available |
| §25.629 | Aeroelastic stability requirements | CS25-13 | CS25-1 | 2 | ✓ Text available |
| §25.631 | Bird strike damage | CS25-13 | CS25-0 | 1 | ✓ Text available |
| §25.651 | Proof of strength | CS25-13 | CS25-0 | 0 | ✓ Text available |
| §25.655 | Installation | CS25-13 | CS25-0 | 0 | ✓ Text available |
| §25.657 | Hinges | CS25-13 | CS25-0 | 0 | ✓ Text available |
| §25.671 | General | CS25-13 | CS25-0 | 2 | ✓ Text available |
| §25.672 | Stability augmentation and automatic and power- operated systems | CS25-13 | CS25-0 | 2 | ✓ Text available |
| §25.675 | Stops | CS25-13 | CS25-0 | 0 | ✓ Text available |
| §25.677 | Trim systems | CS25-13 | CS25-0 | 0 | ✓ Text available |
| §25.679 | Control system gust locks | CS25-13 | CS25-0 | 1 | ✓ Text available |
| §25.681 | Limit load static tests | CS25-13 | CS25-0 | 0 | ✓ Text available |
| §25.683 | Operation tests | CS25-13 | CS25-0 | 0 | ✓ Text available |
| §25.685 | Control system details | CS25-13 | CS25-0 | 1 | ✓ Text available |
| §25.689 | Cable systems | CS25-13 | CS25-0 | 0 | ✓ Text available |
| §25.693 | Joints | CS25-13 | CS25-0 | 0 | ✓ Text available |
| §25.697 | Lift and drag devices, controls | CS25-13 | CS25-0 | 0 | ✓ Text available |
| §25.699 | Lift and drag device indicator | CS25-13 | CS25-0 | 0 | ✓ Text available |
| §25.701 | Flap and slat interconnection | CS25-13 | CS25-0 | 1 | ✓ Text available |
| §25.703 | Take-off warning system | CS25-13 | CS25-0 | 0 | ✓ Text available |
| §25.721 | General (See AMC 25.963(d)) | CS25-13 | CS25-3 | 0 | ✓ Text available |
| §25.723 | Shock absorption tests | CS25-13 | CS25-0 | 0 | ✓ Text available |
| §25.729 | Extending and retracting mechanisms | CS25-13 | CS25-4 | 2 | ✓ Text available |
| §25.731 | Wheels | CS25-13 | CS25-0 | 0 | ✓ Text available |
| §25.733 | Tyres | CS25-13 | CS25-0 | 1 | ✓ Text available |
| §25.735 | Brakes and braking systems | CS25-13 | CS25-2 | 1 | ✓ Text available |
| §25.745 | Nose-wheel steering | CS25-13 | CS25-13 | 1 | ✓ Text available |
| §25.771 | Pilot compartment | CS25-13 | CS25-0 | 0 | ✓ Text available |
| §25.772 | Pilot compartment doors | CS25-13 | CS25-0 | 0 | ✓ Text available |
| §25.773 | Pilot compartment view | CS25-13 | CS25-4 | 3 | ✓ Text available |
| §25.775 | Windshields and windows | CS25-13 | CS25-0 | 1 | ✓ Text available |
| §25.777 | Cockpit controls | CS25-13 | CS25-13 | 0 | ✓ Text available |
| §25.779 | Motion and effect of cockpit controls | CS25-13 | CS25-0 | 0 | ✓ Text available |
| §25.781 | Cockpit control knob shape | CS25-13 | CS25-0 | 0 | ✓ Text available |
| §25.783 | Fuselage Doors | CS25-13 | CS25-4 | 1 | ✓ Text available |
| §25.785 | Seats, berths, safety belts and harnesses | CS25-13 | CS25-13 | 2 | ✓ Text available |
| §25.787 | Stowage compartments | CS25-13 | CS25-0 | 1 | ✓ Text available |
| §25.789 | Retention of items of mass in passenger and crew compartments and galleys | CS25-13 | CS25-0 | 0 | ✓ Text available |
| §25.791 | Passenger information signs and placards | CS25-13 | CS25-0 | 1 | ✓ Text available |
| §25.793 | Floor surfaces | CS25-13 | CS25-0 | 1 | ✓ Text available |
| §25.795 | Security considerations | CS25-13 | CS25-9 | 2 | ✓ Text available |
| §25.801 | Ditching | CS25-13 | CS25-0 | 2 | ✓ Text available |
| §25.803 | Emergency evacuation | CS25-13 | CS25-0 | 0 | ✓ Text available |
| §25.807 | Emergency exits | CS25-13 | CS25-12 | 5 | ✓ Text available |
| §25.809 | Emergency exit arrangement | CS25-13 | CS25-12 | 2 | ✓ Text available |
| §25.810 | Emergency egress assisting means and escape routes | CS25-13 | CS25-13 | 3 | ✓ Text available |
| §25.811 | Emergency exit marking | CS25-13 | CS25-3 | 3 | ✓ Text available |
| §25.812 | Emergency lighting | CS25-13 | CS25-12 | 2 | ✓ Text available |
| §25.813 | Emergency exit access and ease of operation | CS25-13 | CS25-12 | 2 | ✓ Text available |
| §25.815 | Width of aisle | CS25-13 | CS25-0 | 0 | ✓ Text available |
| §25.817 | Maximum number of seats abreast | CS25-13 | CS25-0 | 0 | ✓ Text available |
| §25.819 | Lower deck service compartments (including galleys) | CS25-13 | CS25-0 | 1 | ✓ Text available |
| §25.820 | Lavatory doors | CS25-13 | CS25-4 | 0 | ✓ Text available |
| §25.831 | Ventilation | CS25-13 | CS25-0 | 2 | ✓ Text available |
| §25.832 | Cabin ozone concentration | CS25-13 | CS25-0 | 0 | ✓ Text available |
| §25.833 | Combustion heating systems | CS25-13 | CS25-0 | 0 | ✓ Text available |
| §25.841 | Pressurised cabins | CS25-13 | CS25-0 | 1 | ✓ Text available |
| §25.843 | Tests for pressurised cabins | CS25-13 | CS25-0 | 0 | ✓ Text available |
| §25.851 | Fire extinguishers | CS25-13 | CS25-12 | 2 | ✓ Text available |
| §25.853 | Compartment interiors | CS25-13 | CS25-12 | 1 | ✓ Text available |
| §25.854 | Lavatory fire protection | CS25-13 | CS25-0 | 1 | ✓ Text available |
| §25.855 | Cargo or baggage compartments | CS25-13 | CS25-13 | 1 | ✓ Text available |
| §25.856 | Thermal/acoustic insulation materials | CS25-13 | CS25-6 | 2 | ✓ Text available |
| §25.857 | Cargo compartment classification | CS25-13 | CS25-8 | 1 | ✓ Text available |
| §25.858 | Cargo or baggage compartment smoke or fire detection systems | CS25-13 | CS25-3 | 0 | ✓ Text available |
| §25.859 | Combustion heater fire protection | CS25-13 | CS25-0 | 0 | ✓ Text available |
| §25.863 | Flammable fluid fire protection | CS25-13 | CS25-0 | 1 | ✓ Text available |
| §25.865 | Fire protection of flight controls, engine mounts, and other flight structure | CS25-13 | CS25-0 | 0 | ✓ Text available |
| §25.867 | Fire protection: other components | CS25-13 | CS25-0 | 0 | ✓ Text available |
| §25.869 | Fire protection: systems | CS25-13 | CS25-5 | 2 | ✓ Text available |
| §25.871 | Levelling means | CS25-13 | CS25-0 | 0 | ✓ Text available |
| §25.875 | Reinforcement near propellers | CS25-13 | CS25-0 | 0 | ✓ Text available |
| §25.899 | Electrical bonding and protection against static electricity | CS25-13 | CS25-0 | 0 | ✓ Text available |
Subpart E — Powerplant CS-25 80 sections
| Section | Title | Cut-off | Text version | Changed since | Status |
|---|---|---|---|---|---|
| §25.901 | Installation | CS25-13 | CS25-8 | 2 | ✓ Text available |
| §25.903 | Engines | CS25-13 | CS25-0 | 2 | ✓ Text available |
| §25.904 | Automatic Takeoff Thrust | CS25-13 | CS25-0 | 0 | ✓ Text available |
| §25.905 | Propellers | CS25-13 | CS25-3 | 1 | ✓ Text available |
| §25.907 | Propeller vibration | CS25-13 | CS25-3 | 0 | ✓ Text available |
| §25.925 | Propeller clearance | CS25-13 | CS25-0 | 1 | ✓ Text available |
| §25.929 | Propeller de-icing | CS25-13 | CS25-0 | 2 | ✓ Text available |
| §25.933 | Reversing systems | CS25-13 | CS25-1 | 2 | ✓ Text available |
| §25.934 | Turbo-jet engine thrust reverser system tests | CS25-13 | CS25-0 | 0 | ✓ Text available |
| §25.937 | Turbo-propeller-drag limiting systems | CS25-13 | CS25-0 | 0 | ✓ Text available |
| §25.939 | Turbine engine operating characteristics | CS25-13 | CS25-0 | 0 | ✓ Text available |
| §25.941 | Inlet, engine, and exhaust compatibility | CS25-13 | CS25-3 | 0 | ✓ Text available |
| §25.943 | Negative acceleration | CS25-13 | CS25-0 | 0 | ✓ Text available |
| §25.945 | Thrust or power augmentation system | CS25-13 | CS25-0 | 0 | ✓ Text available |
| §25.951 | General | CS25-13 | CS25-13 | 0 | ✓ Text available |
| §25.952 | Fuel system analysis and test | CS25-13 | CS25-0 | 0 | ✓ Text available |
| §25.953 | Fuel system independence | CS25-13 | CS25-0 | 0 | ✓ Text available |
| §25.954 | Fuel system lightning protection | CS25-13 | CS25-0 | 2 | ✓ Text available |
| §25.955 | Fuel flow | CS25-13 | CS25-0 | 1 | ✓ Text available |
| §25.957 | Flow between interconnected tanks | CS25-13 | CS25-0 | 0 | ✓ Text available |
| §25.959 | Unusable fuel supply | CS25-13 | CS25-0 | 0 | ✓ Text available |
| §25.961 | Fuel system hot weather operation | CS25-13 | CS25-0 | 0 | ✓ Text available |
| §25.963 | Fuel tanks: general | CS25-13 | CS25-3 | 3 | ✓ Text available |
| §25.965 | Fuel tank tests | CS25-13 | CS25-0 | 0 | ✓ Text available |
| §25.967 | Fuel tank installations | CS25-13 | CS25-0 | 1 | ✓ Text available |
| §25.969 | Fuel tank expansion space | CS25-13 | CS25-0 | 0 | ✓ Text available |
| §25.971 | Fuel tank sump | CS25-13 | CS25-0 | 0 | ✓ Text available |
| §25.973 | Fuel tank filler connection | CS25-13 | CS25-0 | 0 | ✓ Text available |
| §25.975 | Fuel tank vents | CS25-13 | CS25-0 | 2 | ✓ Text available |
| §25.977 | Fuel tank outlet | CS25-13 | CS25-0 | 0 | ✓ Text available |
| §25.979 | Pressure fuelling system | CS25-13 | CS25-0 | 1 | ✓ Text available |
| §25.981 | Fuel tank explosion prevention | CS25-13 | CS25-9 | 3 | ✓ Text available |
| §25.991 | Fuel pumps | CS25-13 | CS25-5 | 0 | ✓ Text available |
| §25.993 | Fuel system lines and fittings | CS25-13 | CS25-0 | 0 | ✓ Text available |
| §25.994 | Fuel system components | CS25-13 | CS25-3 | 0 | ✓ Text available |
| §25.995 | Fuel valves | CS25-13 | CS25-0 | 0 | ✓ Text available |
| §25.997 | Fuel strainer or filter | CS25-13 | CS25-0 | 0 | ✓ Text available |
| §25.999 | Fuel systems drains | CS25-13 | CS25-0 | 0 | ✓ Text available |
| §25.1001 | Fuel jettisoning system | CS25-13 | CS25-0 | 0 | ✓ Text available |
| §25.1011 | General | CS25-13 | CS25-0 | 0 | ✓ Text available |
| §25.1013 | Oil tanks | CS25-13 | CS25-0 | 0 | ✓ Text available |
| §25.1015 | Oil tank tests | CS25-13 | CS25-0 | 0 | ✓ Text available |
| §25.1017 | Oil lines and fittings | CS25-13 | CS25-0 | 0 | ✓ Text available |
| §25.1019 | Oil strainer or filter | CS25-13 | CS25-0 | 0 | ✓ Text available |
| §25.1021 | Oil system drains | CS25-13 | CS25-0 | 0 | ✓ Text available |
| §25.1023 | Oil radiators | CS25-13 | CS25-0 | 0 | ✓ Text available |
| §25.1025 | Oil valves | CS25-13 | CS25-0 | 0 | ✓ Text available |
| §25.1027 | Propeller feathering system | CS25-13 | CS25-0 | 0 | ✓ Text available |
| §25.1041 | General | CS25-13 | CS25-0 | 0 | ✓ Text available |
| §25.1043 | Cooling tests | CS25-13 | CS25-0 | 1 | ✓ Text available |
| §25.1045 | Cooling test procedures | CS25-13 | CS25-0 | 0 | ✓ Text available |
| §25.1091 | Air intake | CS25-13 | CS25-0 | 1 | ✓ Text available |
| §25.1093 | Air intake system de-icing and anti-icing provisions | CS25-13 | CS25-0 | 3 | ✓ Text available |
| §25.1103 | Air intake system ducts and air duct systems | CS25-13 | CS25-0 | 1 | ✓ Text available |
| §25.1121 | General | CS25-13 | CS25-0 | 1 | ✓ Text available |
| §25.1123 | Exhaust piping | CS25-13 | CS25-0 | 0 | ✓ Text available |
| §25.1141 | Powerplant controls: general | CS25-13 | CS25-1 | 1 | ✓ Text available |
| §25.1143 | Engine controls | CS25-13 | CS25-0 | 0 | ✓ Text available |
| §25.1145 | Ignition switches | CS25-13 | CS25-0 | 0 | ✓ Text available |
| §25.1149 | Propeller speed and pitch controls | CS25-13 | CS25-0 | 0 | ✓ Text available |
| §25.1153 | Propeller feathering controls | CS25-13 | CS25-0 | 0 | ✓ Text available |
| §25.1155 | Reverse thrust and propeller pitch settings below the flight regime | CS25-13 | CS25-0 | 1 | ✓ Text available |
| §25.1161 | Fuel jettisoning system controls | CS25-13 | CS25-0 | 0 | ✓ Text available |
| §25.1163 | Powerplant accessories | CS25-13 | CS25-0 | 0 | ✓ Text available |
| §25.1165 | Engine ignition systems | CS25-13 | CS25-0 | 0 | ✓ Text available |
| §25.1167 | Accessory gearboxes | CS25-13 | CS25-0 | 0 | ✓ Text available |
| §25.1181 | Designated fire zones: regions included | CS25-13 | CS25-0 | 0 | ✓ Text available |
| §25.1182 | Nacelle areas behind firewalls, and engine pod attaching structures containing flammable fluid lines | CS25-13 | CS25-0 | 1 | ✓ Text available |
| §25.1183 | Flammable fluid-carrying components | CS25-13 | CS25-0 | 0 | ✓ Text available |
| §25.1185 | Flammable fluids | CS25-13 | CS25-0 | 0 | ✓ Text available |
| §25.1187 | Drainage and ventilation of fire zones | CS25-13 | CS25-0 | 0 | ✓ Text available |
| §25.1189 | Shut-off means | CS25-13 | CS25-1 | 0 | ✓ Text available |
| §25.1191 | Firewalls | CS25-13 | CS25-0 | 0 | ✓ Text available |
| §25.1193 | Cowling and nacelle skin | CS25-13 | CS25-13 | 3 | ✓ Text available |
| §25.1195 | Fire-extinguisher systems | CS25-13 | CS25-0 | 1 | ✓ Text available |
| §25.1197 | Fire-extinguishing agents | CS25-13 | CS25-12 | 0 | ✓ Text available |
| §25.1199 | Extinguishing agent containers | CS25-13 | CS25-0 | 0 | ✓ Text available |
| §25.1201 | Fire extinguishing system materials | CS25-13 | CS25-0 | 0 | ✓ Text available |
| §25.1203 | Fire-detector system | CS25-13 | CS25-5 | 0 | ✓ Text available |
| §25.1207 | Compliance | CS25-13 | CS25-0 | 0 | ✓ Text available |
Subpart F — Equipment CS-25 60 sections
| Section | Title | Cut-off | Text version | Changed since | Status |
|---|---|---|---|---|---|
| §25.1301 | Function and installation | CS25-13 | CS25-5 | 0 | ✓ Text available |
| §25.1302 | Installed systems and equipment for use by the flight crew | CS25-13 | CS25-3 | 1 | ✓ Text available |
| §25.1303 | Flight and navigation instruments | CS25-13 | CS25-0 | 3 | ✓ Text available |
| §25.1305 | Powerplant instruments | CS25-13 | CS25-12 | 2 | ✓ Text available |
| §25.1307 | Miscellaneous equipment | CS25-13 | CS25-0 | 0 | ✓ Text available |
| §25.1309 | Equipment, systems and installations | CS25-13 | CS25-6 | 3 | ✓ Text available |
| §25.1310 | Power source capacity and distribution | CS25-13 | CS25-0 | 1 | ✓ Text available |
| §25.1315 | Negative acceleration | CS25-13 | CS25-0 | 1 | ✓ Text available |
| §25.1316 | Electrical and electronic system lightning | CS25-13 | CS25-0 | 1 | ✓ Text available |
| §25.1321 | Arrangement and visibility | CS25-13 | CS25-0 | 0 | ✓ Text available |
| §25.1322 | Flight Crew Alerting | CS25-1 | CS25-0 | 1 | ✓ Text available |
| §25.1323 | Airspeed indicating system | CS25-13 | CS25-0 | 3 | ✓ Text available |
| §25.1325 | Static pressure systems | CS25-13 | CS25-0 | 1 | ✓ Text available |
| §25.1326 | Flight instrument external probes heating systems | CS25-13 | CS25-0 | 1 | ✓ Text available |
| §25.1327 | Direction Indicator | CS25-13 | CS25-0 | 0 | ✓ Text available |
| §25.1329 | Flight Guidance System | CS25-13 | CS25-4 | 0 | ✓ Text available |
| §25.1331 | Instruments using a power supply | CS25-13 | CS25-0 | 0 | ✓ Text available |
| §25.1333 | Instrument systems | CS25-13 | CS25-0 | 1 | ✓ Text available |
| §25.1337 | Powerplant instruments | CS25-13 | CS25-0 | 0 | ✓ Text available |
| §25.1351 | General | CS25-13 | CS25-0 | 1 | ✓ Text available |
| §25.1353 | Electrical equipment and installations | CS25-13 | CS25-5 | 1 | ✓ Text available |
| §25.1355 | Distribution system | CS25-13 | CS25-0 | 1 | ✓ Text available |
| §25.1357 | Circuit protective devices | CS25-13 | CS25-5 | 1 | ✓ Text available |
| §25.1360 | Precautions against injury | CS25-13 | CS25-0 | 1 | ✓ Text available |
| §25.1362 | Electrical supplies for emergency conditions | CS25-13 | CS25-0 | 0 | ✓ Text available |
| §25.1363 | Electrical system tests | CS25-13 | CS25-0 | 0 | ✓ Text available |
| §25.1365 | Electrical appliances, motors and transformers | CS25-13 | CS25-2 | 2 | ✓ Text available |
| §25.1381 | Instrument lights | CS25-13 | CS25-0 | 0 | ✓ Text available |
| §25.1383 | Landing lights | CS25-13 | CS25-0 | 0 | ✓ Text available |
| §25.1385 | Position light system installation | CS25-13 | CS25-0 | 0 | ✓ Text available |
| §25.1387 | Position light system dihedral angles | CS25-13 | CS25-0 | 1 | ✓ Text available |
| §25.1389 | Position light distribution and intensities | CS25-13 | CS25-0 | 0 | ✓ Text available |
| §25.1391 | Minimum intensities in the horizontal plane of forward and rear position lights | CS25-13 | CS25-0 | 1 | ✓ Text available |
| §25.1393 | Minimum intensities in any vertical plane of forward and rear position lights | CS25-13 | CS25-0 | 0 | ✓ Text available |
| §25.1395 | Maximum intensities in over-lapping beams of forward and rear position lights | CS25-13 | CS25-0 | 0 | ✓ Text available |
| §25.1397 | Colour specifications | CS25-13 | CS25-0 | 0 | ✓ Text available |
| §25.1401 | Anti-collision light system | CS25-13 | CS25-0 | 1 | ✓ Text available |
| §25.1403 | Wing icing detection lights | CS25-13 | CS25-0 | 1 | ✓ Text available |
| §25.1411 | General | CS25-13 | CS25-5 | 0 | ✓ Text available |
| §25.1415 | Ditching equipment | CS25-13 | CS25-0 | 0 | ✓ Text available |
| §25.1419 | Ice Protection | CS25-13 | CS25-7 | 0 | ✓ Text available |
| §25.1421 | Megaphones | CS25-13 | CS25-0 | 0 | ✓ Text available |
| §25.1423 | Public address system | CS25-13 | CS25-2 | 0 | ✓ Text available |
| §25.1431 | Electronic equipment | CS25-13 | CS25-0 | 0 | ✓ Text available |
| §25.1433 | Vacuum systems | CS25-13 | CS25-0 | 0 | ✓ Text available |
| §25.1435 | Hydraulic Systems | CS25-13 | CS25-2 | 0 | ✓ Text available |
| §25.1436 | Pneumatic systems — high pressure | CS25-13 | CS25-1 | 1 | ✓ Text available |
| §25.1438 | Pressurisation and low pressure pneumatic systems | CS25-13 | CS25-0 | 1 | ✓ Text available |
| §25.1439 | Protective breathing equipment | CS25-13 | CS25-4 | 1 | ✓ Text available |
| §25.1441 | Oxygen equipment and supply | CS25-13 | CS25-0 | 4 | ✓ Text available |
| §25.1443 | Minimum mass flow of supplemental oxygen | CS25-13 | CS25-0 | 1 | ✓ Text available |
| §25.1445 | Equipment standards for the oxygen distributing system | CS25-13 | CS25-0 | 0 | ✓ Text available |
| §25.1447 | Equipment standards for oxygen dispensing units | CS25-13 | CS25-13 | 2 | ✓ Text available |
| §25.1449 | Means for determining use of oxygen | CS25-13 | CS25-0 | 1 | ✓ Text available |
| §25.1450 | Chemical oxygen generators | CS25-13 | CS25-0 | 1 | ✓ Text available |
| §25.1453 | Protection of oxygen equipment from rupture | CS25-13 | CS25-4 | 1 | ✓ Text available |
| §25.1455 | Draining of fluids subject to freezing | CS25-13 | CS25-0 | 0 | ✓ Text available |
| §25.1457 | Cockpit voice recorders | CS25-13 | CS25-0 | 3 | ✓ Text available |
| §25.1459 | Flight data recorders | CS25-13 | CS25-11 | 3 | ✓ Text available |
| §25.1461 | Equipment containing high-energy rotors | CS25-13 | CS25-0 | 0 | ✓ Text available |
Subpart G — Operating Limitations And Information CS-25 35 sections
| Section | Title | Cut-off | Text version | Changed since | Status |
|---|---|---|---|---|---|
| §25.1501 | General | CS25-13 | CS25-13 | 0 | ✓ Text available |
| §25.1503 | Airspeed limitations: general | CS25-13 | CS25-0 | 0 | ✓ Text available |
| §25.1505 | Maximum operating limit speed | CS25-13 | CS25-0 | 0 | ✓ Text available |
| §25.1507 | Manoeuvring speed | CS25-13 | CS25-0 | 0 | ✓ Text available |
| §25.1511 | Flap extended speed | CS25-13 | CS25-0 | 0 | ✓ Text available |
| §25.1513 | Minimum control speed | CS25-13 | CS25-0 | 0 | ✓ Text available |
| §25.1515 | Landing gear speeds | CS25-13 | CS25-0 | 0 | ✓ Text available |
| §25.1516 | Other speed limitations | CS25-13 | CS25-0 | 0 | ✓ Text available |
| §25.1517 | Rough air speed, VRA | CS25-13 | CS25-1 | 0 | ✓ Text available |
| §25.1519 | Weight, centre of gravity and weight distribution | CS25-13 | CS25-0 | 1 | ✓ Text available |
| §25.1521 | Powerplant limitations | CS25-13 | CS25-0 | 1 | ✓ Text available |
| §25.1523 | Minimum flight crew | CS25-13 | CS25-0 | 1 | ✓ Text available |
| §25.1525 | Kinds of operation | CS25-13 | CS25-0 | 0 | ✓ Text available |
| §25.1527 | Ambient air temperature and operating altitude | CS25-13 | CS25-0 | 0 | ✓ Text available |
| §25.1529 | Instructions for Continued | CS25-13 | CS25-0 | 0 | ✓ Text available |
| §25.1531 | Manoeuvring flight load factors | CS25-13 | CS25-0 | 0 | ✓ Text available |
| §25.1533 | Additional operating limitations | CS25-13 | CS25-0 | 2 | ✓ Text available |
| §25.1535 | ETOPS Design approval | CS25-13 | CS25-10 | 2 | ✓ Text available |
| §25.1541 | General | CS25-13 | CS25-0 | 0 | ✓ Text available |
| §25.1543 | Instrument markings; general | CS25-13 | CS25-0 | 0 | ✓ Text available |
| §25.1545 | Airspeed limitation information | CS25-13 | CS25-0 | 2 | ✓ Text available |
| §25.1547 | Magnetic direction indicator | CS25-13 | CS25-0 | 0 | ✓ Text available |
| §25.1549 | Powerplant instruments | CS25-13 | CS25-0 | 0 | ✓ Text available |
| §25.1551 | Oil quantity indicator | CS25-13 | CS25-0 | 0 | ✓ Text available |
| §25.1553 | Fuel quantity indicator | CS25-13 | CS25-0 | 0 | ✓ Text available |
| §25.1555 | Control markings | CS25-13 | CS25-0 | 0 | ✓ Text available |
| §25.1557 | Miscellaneous markings and placards | CS25-13 | CS25-0 | 1 | ✓ Text available |
| §25.1561 | Safety equipment | CS25-13 | CS25-0 | 0 | ✓ Text available |
| §25.1563 | Airspeed placard | CS25-13 | CS25-0 | 0 | ✓ Text available |
| §25.1581 | General | CS25-13 | CS25-0 | 0 | ✓ Text available |
| §25.1583 | Operating limitations | CS25-13 | CS25-1 | 2 | ✓ Text available |
| §25.1585 | Operating procedures | CS25-13 | CS25-0 | 0 | ✓ Text available |
| §25.1587 | Performance information | CS25-13 | CS25-0 | 2 | ✓ Text available |
| §25.1591 | Take-off performance information for operations on slippery wet and contaminated runways | CS25-13 | CS25-5 | 1 | ✓ Text available |
| §25.1593 | Exposure to volcanic cloud hazards | CS25-13 | CS25-13 | 0 | ✓ Text available |
Subpart H — Electrical Wiring Interconnection System CS-25 15 sections
| Section | Title | Cut-off | Text version | Changed since | Status |
|---|---|---|---|---|---|
| §25.1701 | Definition | CS25-13 | CS25-5 | 0 | ✓ Text available |
| §25.1703 | Function and Installation; EWIS | CS25-13 | CS25-5 | 0 | ✓ Text available |
| §25.1705 | Systems and Functions; EWIS | CS25-13 | CS25-5 | 0 | ✓ Text available |
| §25.1707 | System Separation; EWIS | CS25-13 | CS25-5 | 0 | ✓ Text available |
| §25.1709 | System Safety; EWIS | CS25-13 | CS25-5 | 0 | ✓ Text available |
| §25.1711 | Component identification; EWIS | CS25-13 | CS25-5 | 0 | ✓ Text available |
| §25.1713 | Fire Protection; EWIS | CS25-13 | CS25-5 | 0 | ✓ Text available |
| §25.1715 | Electrical bonding and protection against static | CS25-13 | CS25-5 | 0 | ✓ Text available |
| §25.1717 | Circuit protective devices; EWIS | CS25-13 | CS25-5 | 0 | ✓ Text available |
| §25.1719 | Accessibility Provisions; EWIS | CS25-13 | CS25-5 | 0 | ✓ Text available |
| §25.1721 | Protection of EWIS | CS25-13 | CS25-5 | 0 | ✓ Text available |
| §25.1723 | Flammable fluid | CS25-13 | CS25-5 | 0 | ✓ Text available |
| §25.1725 | Powerplants; EWIS | CS25-13 | CS25-5 | 0 | ✓ Text available |
| §25.1727 | Flammable Fluid Shutoff | CS25-13 | CS25-5 | 0 | ✓ Text available |
| §25.1729 | Instructions for Continued Airworthiness; EWIS | CS25-13 | CS25-5 | 0 | ✓ Text available |
Subpart H — Electrical Wiring Interconnection Systems CS-25 1 section
| Section | Title | Cut-off | Text version | Changed since | Status |
|---|---|---|---|---|---|
| §25.1731 | Powerplant and APU fire detector system; EWIS | CS25-13 | CS25-13 | 4 | ✓ Text available |
Subpart J — Gas Turbine Auxiliary Power Unit Installations CS-25 2 sections ! 1 text missing
Subpart J — Auxiliary Power Unit Installations CS-25 10 sections
| Section | Title | Cut-off | Text version | Changed since | Status |
|---|---|---|---|---|---|
| CS-25 C25 | Appendix C | CS25-13 | CS25-7 | 2 | ✓ Text available |
| CS-25 F25 | Appendix F | CS25-13 | CS25-12 | 2 | ✓ Text available |
| CS-25 H25 | Instructions for Continued Airworthiness | CS25-13 | CS25-8 | 6 | ✓ Text available |
| CS-25 I25 | Automatic Takeoff Thrust Control System (ATTCS) | CS25-13 | CS25-0 | 1 | ✓ Text available |
| CS-25 J25 | Emergency Demonstration | CS25-13 | CS25-2 | 1 | ✓ Text available |
| CS-25 K25 | Interaction of Systems and Structure | CS25-13 | CS25-1 | 0 | ✓ Text available |
| CS-25 L25 | Strength Value | CS25-13 | CS25-1 | 0 | ✓ Text available |
| CS-25 M25 | Fuel Tank Flammability Reduction Means (FRM) | CS25-13 | CS25-6 | 0 | ✓ Text available |
| CS-25 N25 | Fuel Tank Flammability Exposure | CS25-13 | CS25-6 | 2 | ✓ Text available |
| CS-25 Q25 | Additional airworthiness requirements for approval of a Steep Approach Landing (SAL) capability | CS25-13 | CS25-13 | 3 | ✓ Text available |