DRS

Dek Regulatory System

Welcome to the World of Certification!

§23.2325 Fire protection

CS-23 · Subpart D — Design And · at CS23-6 (current)

Text in force at CS23-6: from CS23-5, effective 15 Aug 2017.

(a) The aeroplane is designed to minimise the risk of fire initiation due to: (1) anticipated heat or energy dissipation or system failures or overheat that are expected to generate heat sufficient to ignite a fire; (2) ignition of flammable fluids, gases or vapours; and (3) fire-propagating or -initiating system characteristics (e.g. oxygen systems). (b) The aeroplane is designed to minimise the risk of fire propagation by: (1) providing adequate fire or smoke awareness and extinguishing means when practical; (2) application of self-extinguishing, flame-resistant, or fireproof materials that are adequate to the application, location and certification level; or (3) specifying and designing designated fire zones that meet the specifications of CS 23.2330.

ED Decision 2017/013/R · Source

Report an issue

Report an issue

Is something wrong with what you are looking at? Tell the maintainer; the report is filed against this page.

What kind of issue is it? (required)

Reports are posted publicly on GitHub with the address of this page. Please don't include personal information.