DRS

Dek Regulatory System

Welcome to the World of Certification!

§27.1365 Electric cables.

14 CFR 27 · Equipment · Electrical Systems and Equipment · at 27-51 (current)

Text in force at 27-51: from 27-35, effective 11 Sep 1998.

(a) Each electric connecting cable must be of adequate capacity. (b) Each cable that would overheat in the event of circuit overload or fault must be at least flame resistant and may not emit dangerous quantities of toxic fumes. [(c) Insulation on electrical wire and cable installed in the rotorcraft must be self-extinguishing when tested in accordance with Appendix F, Part I(a)(3) of part 25 of this chapter.]

63 FR 43285 · Source

Report an issue