DRS

Dek Regulatory System

Welcome to the World of Certification!

§25.977 Fuel tank outlet.

14 CFR 25 · Powerplant · Fuel System · at 25-153 (current)

Text in force at 25-153: from 25-36, effective 31 Oct 1974.

(a) There must be a fuel strainer for the fuel tank outlet or for the booster pump. This strainer must-- (1) For reciprocating engine powered airplanes, have 8 to 16 meshes per inch; and (2) For turbine engine powered airplanes, prevent the passage of any object that could restrict fuel flow or damage any fuel system component. [(b) [Reserved.]] (c) The clear area of each fuel tank outlet strainer must be at least five times the area of the outlet line. (d) The diameter of each strainer must be at least that of the fuel tank outlet. (e) Each finger strainer must be accessible for inspection and cleaning.

39 FR 35460 · Source

Report an issue

Report an issue

Is something wrong with what you are looking at? Tell the maintainer; the report is filed against this page.

What kind of issue is it? (required)

Reports are posted publicly on GitHub with the address of this page. Please don't include personal information.