§23.977 Fuel tank outlet.

14 CFR 23 · Powerplant · Fuel System · at 23-63 (current)

Text in force at 23-63: from 23-43, effective 10 May 1993.

(a) There must be a fuel strainer for the fuel tank outlet or for the booster pump. This strainer must-- (1) For reciprocating engine powered airplanes, have 8 to 16 meshes per inch; and (2) For turbine engine powered airplanes, prevent the passage of any object that could restrict fuel flow or damage any fuel system component. (b) The clear area of each fuel tank outlet strainer must be at least five times the area of the outlet line. (c) The diameter of each strainer must be at least that of the fuel tank outlet. [(d) Each strainer must be accessible for inspection and cleaning.]

58 FR 18973 · Source

Report an issue