§25.1731 Powerplant and APU fire detector system: EWIS

14 CFR 25 · Electrical Wiring Interconnection Systems (EWIS) · at 25-153 (current)

Text in force at 25-153: from 25-123, effective 10 Dec 2007.

(a) EWIS that are part of each fire or overheat detector system in a fire zone must be fire-resistant. (b) No EWIS component of any fire or overheat detector system for any fire zone may pass through another fire zone, unless: (1) It is protected against the possibility of false warnings resulting from fires in zones through which it passes; or (2) Each zone involved is simultaneously protected by the same detector and extinguishing system. (c) EWIS that are part of each fire or overheat detector system in a fire zone must meet the requirements of Sec. 25.1203.

72 FR 63406 · Source

Report an issue