DRS

Dek Regulatory System

Welcome to the World of Certification!

§27.1435 Hydraulic systems.

14 CFR 27 · Equipment · Safety Equipment · at 27-51 (current)

Text in force at 27-51: from 27-0, effective 1 Feb 1965.

(a) Design. Each hydraulic system and its elements must withstand, without yielding, any structural loads expected in addition to hydraulic loads. (b) Tests. Each system must be substantiated by proof pressure tests. When proof tested, no part of any system may fail, malfunction, or experience a permanent set. The proof load of each system must be at least 1.5 times the maximum operating pressure of that system. (c) Accumulators. No hydraulic accumulator or pressurized reservoir may be installed on the engine side of any firewall unless it is an integral part of an engine.

29 FR 15695 · Source

Report an issue

Report an issue

Is something wrong with what you are looking at? Tell the maintainer; the report is filed against this page.

What kind of issue is it? (required)

Reports are posted publicly on GitHub with the address of this page. Please don't include personal information.