§29.861 Fire protection of structure, controls, and other parts.

14 CFR 29 · Design and Construction · Fire Protection · at 29-59 (current)

Text in force at 29-59: from 29-30, effective 5 Apr 1990.

Each part of the structure, controls, and the rotor mechanism, and other parts essential to controlled landing and (for category A) flight that would be affected by powerplant fires must be isolated under Sec. 29.1191, or must be-- (a) For category A rotorcraft, fireproof; and [(b) For Category B rotorcraft, fireproof or protected so that they can perform their essential functions for at least 5 minutes under any foreseeable powerplant fire conditions.]

55 FR 8003 · Source