DRS

Dek Regulatory System

Welcome to the World of Certification!

§29.831 Ventilation.

14 CFR 29 · Design and Construction · Personnel and Cargo Accommodations · at 29-59 (current)

Text in force at 29-59: from 29-0, effective 1 Feb 1965.

(a) Each passenger and crew compartment must be ventilated, and each crew compartment must have enough fresh air (but not less than 10 cu. ft. per minute per crewmember) to let crewmembers perform their duties without undue discomfort or fatigue. (b) Crew and passenger compartment air must be free from harmful or hazardous concentrations of gases or vapors. (c) The concentration of carbon monoxide may not exceed one part in 20,000 parts of air during forward flight. If the concentration exceeds this value under other conditions, there must be suitable operating restrictions. (d) There must be means to ensure compliance with paragraphs (b) and (c) of this section under any reasonably probable failure of any ventilating, heating, or other system or equipment.

29 FR 16150 · Source

Report an issue