(a) The rotorcraft must be protected against catastrophic effects from lightning.
(b) For metallic components, compliance with paragraph (a) of this section may be shown by--
(1) Electrically bonding the components properly to the airframe; or
(2) Designing the components so that a strike will not endanger the rotorcraft.
(c) For nonmetallic components, compliance with paragraph (a) of this section may be shown by--
(1) Designing the components to minimize the effect of a strike; or
(2) Incorporating acceptable means of diverting the resulting electrical current so as not to endanger the rotorcraft.
(d) The electrical bonding and protection against lightning and static electricity must--
(1) Minimize the accumulation of electrostatic charge;
(2) Minimize the risk of electric shock to crew, passengers, and service and maintenance personnel using normal precautions;
(3) Provide an electrical return path, under both normal and fault conditions, on rotorcraft having grounded electrical systems; and
[(4) Reduce to an acceptable level the effects of static electricity on the functioning of essential electrical and electronic equipment.]