DRS

Dek Regulatory System

Welcome to the World of Certification!

§25.343 Design fuel and oil loads.

14 CFR 25 · Structure · Flight Maneuver and Gust Conditions · at 25-153 (current)

Text in force at 25-153: from 25-141, effective 9 Feb 2015.

(a) The disposable load combinations must include each fuel and oil load in the range from zero fuel and oil to the selected maximum fuel and oil load. A structural reserve fuel condition, not exceeding 45 minutes of fuel under the operating conditions in Sec. 25.1001(e) and (f), as applicable, may be selected. (b) If a structural reserve fuel condition is selected, it must be used as the minimum fuel weight condition for showing compliance with the flight load requirements as prescribed in this subpart. In addition-- (1) The structure must be designed for a condition of zero fuel in and oil the wing at limit loads corresponding to-- (i) A maneuvering load factor of +2.25; and (ii) The gust and turbulence conditions of § 25.341(a) and (b), but assuming 85% of the gust velocities prescribed in § 25.341(a)(4) and 85% of the turbulence intensities prescribed in § 25.341(b)(3). (2) Fatigue evaluation of the structure must account for any increase in operating stresses resulting from the design condition of paragraph (b)(1) of this section; and (3) The flutter, deformation, and vibration requirements must also be met with zero fuel.

79 FR 73468 · Source

Report an issue

Report an issue

Is something wrong with what you are looking at? Tell the maintainer; the report is filed against this page.

What kind of issue is it? (required)

Reports are posted publicly on GitHub with the address of this page. Please don't include personal information.