§25.1185 Flammable fluids.

14 CFR 25 · Powerplant · Powerplant Fire Protection · at 25-153 (current)

Text in force at 25-153: from 25-94, effective 25 Mar 1998.

(a) Except for the integral oil sumps specified in [Sec. 25.1183(a),] no tank or reservoir that is a part of a system containing flammable fluids or gases may be in a designated fire zone unless the fluid contained, the design of the system, the materials used in the tank, the shut-off means, and all connections, lines, and control provide a degree of safety equal to that which would exist if the tank or reservoir were outside such a zone. (b) There must be at least one-half inch of clear airspace between each tank or reservoir and each firewall or shroud isolating a designated fire zone. (c) Absorbent materials close to flammable fluid system components that might leak must be covered or treated to prevent the absorption of hazardous quantities of fluids.

63 FR 8848 · Source