§25.1017 Oil lines and fittings.

14 CFR 25 · Powerplant · Oil System · at 25-153 (current)

Text in force at 25-153: from 25-0, effective 1 Feb 1965.

(a) Each oil line must meet the requirements of Sec. 25.993 and each oil line and fitting in any designated fire zone must meet the requirements of Sec. 25.1183. (b) Breather lines must be arranged so that-- (1) Condensed water vapor that might freeze and obstruct the line cannot accumulate at any point; (2) The breather discharge does not constitute a fire hazard if foaming occurs or causes emitted oil to strike the pilot's windshield; and (3) The breather does not discharge into the engine air induction system.

29 FR 18291 · Source