§23.971 Fuel tank sump.

14 CFR 23 · Powerplant · Fuel System · at 23-63 (current)

Text in force at 23-63: from 23-43, effective 10 May 1993.

[(a) Each fuel tank must have a drainable sump with an effective capacity, in the normal ground and flight attitudes, of 0.25 percent of the tank capacity, or gallon, whichever is greater. (b) Each fuel tank must allow drainage of any hazardous quantity of water from any part of the tank to its sump with the airplane in the normal ground attitude. (c) Each reciprocating engine fuel system must have a sediment bowl or chamber that is accessible for drainage; has a capacity of 1 ounce for every 20 gallons of fuel tank capacity; and each fuel tank outlet is located so that, in the normal flight attitude, water will drain from all parts of the tank except the sump to the sediment bowl or chamber. (d) Each sump, sediment bowl, and sediment chamber drain required by paragraphs (a), (b), and (c) of this section must comply with the drain provisions of Sec. 23.999(b)(1) and (2).]

58 FR 18972 · Source

Report an issue