§23.1450 Chemical oxygen generators.

14 CFR 23 · Equipment · Miscellaneous Equipment · at 23-63 (current)

Text in force at 23-63: from 23-20, effective 1 Sep 1977.

[(a) For the purpose of this section, a chemical oxygen generator is defined as a device which produces oxygen by chemical reaction. (b) Each chemical oxygen generator must be designed and installed in accordance with the following requirements: (1) Surface temperature developed by the generator during operation may not create a hazard to the airplane or to its occupants. (2) Means must be provided to relieve any internal pressure that may be hazardous. (c) In addition to meeting the requirements in paragraph (b) of this section, each portable chemical oxygen generator that is capable of sustained operation by successive replacement of a generator element must be placarded to show-- (1) The rate of oxygen flow, in liters per minute; (2) The duration of oxygen flow, in minutes, for the replaceable generator element; and (3) A warning that the replaceable generator element may be hot, unless the element construction is such that the surface temperature cannot exceed 100 degrees F.] Notice of Airworthiness Review Program No. 2; Notice No. 75-10; Issued on 02/27/75.

42 FR 36969 · Source

Report an issue