§23.1043 Cooling tests.

14 CFR 23 · Powerplant · Cooling · at 23-63 (current)

Text in force at 23-63: from 23-51, effective 12 Mar 1996.

[(a) General. Compliance with Sec. 23.1041 must be shown on the basis of tests, for which the following apply: (1) If the tests are conducted under ambient atmospheric temperature conditions deviating from the maximum for which approval is requested, the recorded powerplant temperatures must be corrected under paragraphs (c) and (d) of this section, unless a more rational correction method is applicable. (2) No corrected temperature determined under paragraph (a)(1) of this section may exceed established limits. (3) The fuel used during the cooling tests must be of the minimum grade approved for the engine. (4) For turbocharged engines, each turbocharger must be operated through that part of the climb profile for which operation with the turbocharger is requested. (5) For a reciprocating engine, the mixture settings must be the leanest recommended for climb.] (b) Maximum ambient atmospheric temperature. A maximum ambient atmospheric temperature corresponding to sea level conditions of at least 100� F. must be established. The assumed temperature lapse rate is 3.6� F per thousand feet of altitude above sea level until a temperature of -69.7� F. is reached, above which altitude the temperature is considered constant at -69.7� F. However, for winterization installations, the applicant may select a maximum ambient atmospheric temperature corresponding to sea level conditions of less than 100� F. [(c) Correction factor (except for cylinder barrels). Temperatures of engine fluids and powerplant components (except cylinder barrels) for which temperature limits are established, must be corrected by adding to them the difference between the maximum ambient atmospheric temperature for the relevant altitude for which approval has been requested and the temperature of the ambient air at the time of the first occurrence of the maximum fluid or component temperature recorded during the cooling test. (d) Correction factor for cylinder barrel temperatures. Cylinder barrel temperatures must be corrected by adding to them 0.7 times the difference between the maximum ambient atmospheric temperature for the relevant altitude for which approval has been requested and the temperature of the ambient air at the time of the first occurrence of the maximum cylinder barrel temperature recorded during the cooling test.]

61 FR 5137 · Source

Report an issue

Report an issue

Is something wrong with what you are looking at? Tell the maintainer; the report is filed against this page.

What kind of issue is it? (required)

Reports are posted publicly on GitHub with the address of this page. Please don't include personal information.