§29.681 Limit load static tests

CS-29 · Subpart D — Design And Construction · at CS29-12 (current)

Text in force at CS29-12: from CS29-0, effective 14 Nov 2003.

(a) Compliance with the limit load requirements of this Code must be shown by tests in which: (1) The direction of the test loads produces the m ost severe loading in the control system; and (2) Each fitting, pulley , and bracket used in attaching the sy stem to the main structure is included. (b) Compliance must be shown (by analy ses or individual load tests) with the special factor requirements for control sy stem j oints subj ect to angular motion.