§29.305 Strength and deformation

CS-29 · Subpart C — Strength Requirements · at CS29-12 (current)

Text in force at CS29-12: from CS29-0, effective 14 Nov 2003.

(a) The st ructure m ust be abl e t o support limit l oads wi thout det rimental or perm anent deformation. At an y lo ad u p to lim it lo ads, th e deformation may not interfere with safe operation. (b) The st ructure m ust be abl e t o support ultimate loads without failure. This must be shown by: (1) Applying ultimate lo ads to th e structure in a static test for at least 3 seconds; or (2) Dynamic tests sim ulating actu al load application.

ED Decision 2003/016/RM · Source

Report an issue