DRS

Dek Regulatory System

Welcome to the World of Certification!

§29.1141 Powerplant controls: general

CS-29 · Subpart E — Powerplant · at CS29-12 (current)

Text in force at CS29-12: from CS29-0, effective 14 Nov 2003.

(a) Powerplant controls must be located and arranged under C S 29.777 and marked under CS 29.1555. (b) Each control m ust be located so that it cannot be inadvertently operat ed by persons entering, leaving or m oving norm ally i n t he cockpit. (c) Each flexible powerplant control must be approved. (d) Each control must be able to maintain any set position without: (1) Constant attention; or (2) Tendency to creep due t o cont rol loads or vibration. (e) Each control m ust b e ab le to with stand operating loads without excessive deflection. (f) Controls of powerpl ant valves required for safety must have: (1) For manual valves, positive stops or in the case of fuel valves suitable index provisions, in the open and closed position; and (2) For power-assisted valves, a means to indicate to the flight crew when the valve: (i) Is in the fully open or fully closed position; or (ii) Is m oving b etween th e fu lly open and fully closed position.

ED Decision 2003/016/RM · Source

Report an issue

Report an issue

Is something wrong with what you are looking at? Tell the maintainer; the report is filed against this page.

What kind of issue is it? (required)

Reports are posted publicly on GitHub with the address of this page. Please don't include personal information.