DRS

Dek Regulatory System

Welcome to the World of Certification!

§27.999 Fuel system drains

CS-27 · Subpart E — Powerplant · at CS27-10 (current)

Text in force at CS27-10: from CS27-0, effective 14 Nov 2003.

(a) There must be at least one accessible drain at the lowest point in each fuel system to completely drain the system with the rotorcraft in any ground attitude to be expected in service. (b) Each drain required by sub-paragraph (a) must: (1) Discharge clear of all parts of the rotorcraft; (2) Have manual or automatic means to assure positive closure in the off position; and (3) Have a drain valve: (i) That is readily accessible and which can be easily opened and closed; and (ii) That is either located or protected to prevent fuel spillage in the event of a landing with landing gear retracted.

ED Decision 2003/015/RM · Source

Report an issue

Report an issue

Is something wrong with what you are looking at? Tell the maintainer; the report is filed against this page.

What kind of issue is it? (required)

Reports are posted publicly on GitHub with the address of this page. Please don't include personal information.