DRS

Dek Regulatory System

Welcome to the World of Certification!

§27.1395 Maximum intensities in overlapping beams of forward and rear position lights

CS-27 · Subpart F — Equipment · at CS27-10 (current)

Text in force at CS27-10: from CS27-0, effective 14 Nov 2003.

No position light intensity may exceed the applicable values in the following table, except as provided in CS 27.1389(b)(3): Maximum intensity Overlaps Area A Area B (candelas) (candelas) Green in dihedral angle L 10 1 Red in dihedral angle R 10 1 Green in dihedral angle A 5 1 Red in dihedral angle A 5 1 Rear white in dihedral angle L 5 1 Rear white in dihedral angle R 5 1 Where: (a) Area A includes all directions in the adjacent dihedral angle that pass through the light source and intersect the common boundary plane at more than 10° but less than 20°; and (b) Area B includes all directions in the adjacent dihedral angle that pass through the light source and intersect the common boundary plane at more than 20°.

ED Decision 2003/015/RM · Source

Report an issue

Report an issue

Is something wrong with what you are looking at? Tell the maintainer; the report is filed against this page.

What kind of issue is it? (required)

Reports are posted publicly on GitHub with the address of this page. Please don't include personal information.