Text in force at CS27-10: from CS27-0, effective 14 Nov 2003.
No position light intensity may exceed the applicable values in the following table, except as provided in CS 27.1389(b)(3): Maximum intensity Overlaps Area A Area B (candelas) (candelas) Green in dihedral angle L 10 1 Red in dihedral angle R 10 1 Green in dihedral angle A 5 1 Red in dihedral angle A 5 1 Rear white in dihedral angle L 5 1 Rear white in dihedral angle R 5 1 Where:
(a) Area A includes all directions in the adjacent dihedral angle that pass through the light source and intersect the common boundary plane at more than 10° but less than 20°; and
(b) Area B includes all directions in the adjacent dihedral angle that pass through the light source and intersect the common boundary plane at more than 20°.
ED Decision 2003/015/RM · Source