DRS

Dek Regulatory System

Welcome to the World of Certification!

§27.1357 Circuit protective devices

CS-27 · Subpart F — Equipment · at CS27-10 (current)

Text in force at CS27-10: from CS27-0, effective 14 Nov 2003.

(a) Protective devices, such as fuses or circuit breakers, must be installed in each electrical circuit other than: (1) The main circuits of starter motors; and (2) Circuits in which no hazard is presented by their omission. (b) A protective device for a circuit essential to flight safety may not be used to protect any other circuit. (c) Each resettable circuit protective device (‘trip free’ device in which the tripping mechanism cannot be overridden by the operating control) must be designed so that: (1) A manual operation is required to restore service after tripping; and (2) If an overload or circuit fault exists, the device will open the circuit regardless of the position of the operating control. (d) If the ability to reset a circuit breaker or replace a fuse is essential to safety in flight, that circuit breaker or fuse must be located and identified so that it can be readily reset or replaced in flight. (e) If fuses are used, there must be one spare of each rating, or 50% spare fuses of each rating, whichever is greater.

ED Decision 2003/015/RM · Source

Report an issue

Report an issue

Is something wrong with what you are looking at? Tell the maintainer; the report is filed against this page.

What kind of issue is it? (required)

Reports are posted publicly on GitHub with the address of this page. Please don't include personal information.