Text in force at CS25-28: from CS25-0, effective 17 Oct 2003.
No position light intensity may exceed the applicable values in the following table, except as provided in CS 25.1389 (b)(3): Maximum intensity Overlaps Area A Area B candela candela (candles) (candles) Green in dihedral angle L 10 1 Red in dihedral angle R 10 1 Green in dihedral angle A 5 1 Red in dihedral angle A 5 1 Rear white in dihedral 5 1 angle L Rear white in dihedral 5 1 angle R Where –
(a) Area A includes all directions in the adjacent dihedral angle that pass through the light source and intersect the common boundary plane at more than 10º but less than 20º; and
(b) Area B includes all directions in the adjacent dihedral angle that pass through the light source and intersect the common boundary plane at more than 20º.