Text in force at CAR3R-8: from CAR3R-8, effective 13 Dec 1962. OCR text
A master switch arrangement shall be provided to permit expeditious disconnection of all electric power sources from the main bus. The point of disconnection shall be adjacent to the power sources. Load circuits may be connected in such manner that they remain energized after the master switch is opened if they are protected by circuit protective devices, rated at five amperes or less, located adjacent to the electric power source. (Secs. 313(a), 601, 603, 72 Stat. 752, 775, 776; 49 U.S.C, 1354, 1421, 1423) Issued in Washington, D.C., on December 18, 1962, N. E. Hatasy, Administrator, {F.R. Doc, 62-12683; Filed, Dec..26, 1962; 8:45 am.) {As published in the Federal Register 237 F.R, 127467 December 27, 1962) 63—4608