§3.435 Fuel flow rate for pump systems.

CAR 3 (Reissue) · Operation · Powerplant Installations – Reciprocating Engines · at CAR3R-8 (current)

Text in force at CAR3R-8: from CAR3R-0, effective 15 May 1956. OCR text

The fuel flow rate for pump systems (main and reserve supply) shall be 0.9 pound per hour for each take-off horsepower or 125 percent of the actual take-off fuel consumption of the engine, whichever is greater. This flow rate shall be applicable to both the primary engine-driven pump and the emergency pumps and shal! be available when the pump is running at the speed at which it would normally be operating during take-off. In the case of hand-operated pumps, this speed shall be considered to be not more than 60 complete cycles (120 single strokes) per minute.