Text in force at CAR3-14: from CAR3-0, effective 1 Nov 1949. OCR text
The fuel flow rate for pump systems (main and reserve supply) shall be 0.9 pound per hour for each take-off horsepower or 125 percent of the actual take-off fuel consumption of the engine, whichever is greater. This flow rate shall be applicable to both the primary engine-driven pump and the emergency pumps and shall be available when the pump is running at the speed at which it would normally be operating during take-off. In the case of hand-operated pumps, this speed shall be considered to be not more than 60 complete cycles (120 single strokes) per minute.